<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-23 19-06-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 70 kHz 11451 4,7769
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 5,27 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 12 kHz % above 76 kHz: 4,7769 Acquired: 2025/07/23 19.05.54 Total samples: 11451 Equivalent time: 0:09:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,6 dBr MIN: 3,8 dBr AVE: 5,27 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/07/23 19.05.54) 18.52 18.54 18.56 18.58 19.00 19.02 19.04 0 2 4 6 Pm [dBr]